Staff View
A computational study on the steady and transient behavior of data centers

Descriptive

TitleInfo
Title
A computational study on the steady and transient behavior of data centers
Name (type = personal)
NamePart (type = family)
Sunder
NamePart (type = given)
Arvindh
NamePart (type = date)
1994-
DisplayForm
Arvindh Sunder
Role
RoleTerm (authority = RULIB)
author
Name (type = personal)
NamePart (type = family)
Jaluria
NamePart (type = given)
Yogesh
DisplayForm
Yogesh Jaluria
Affiliation
Advisory Committee
Role
RoleTerm (authority = RULIB)
chair
Name (type = corporate)
NamePart
Rutgers University
Role
RoleTerm (authority = RULIB)
degree grantor
Name (type = corporate)
NamePart
School of Graduate Studies
Role
RoleTerm (authority = RULIB)
school
TypeOfResource
Text
Genre (authority = marcgt)
theses
OriginInfo
DateCreated (qualifier = exact)
2018
DateOther (qualifier = exact); (type = degree)
2018-05
CopyrightDate (encoding = w3cdtf); (qualifier = exact)
2018
Place
PlaceTerm (type = code)
xx
Language
LanguageTerm (authority = ISO639-2b); (type = code)
eng
Abstract (type = abstract)
Data center is a facility that has high energy demands to keep the temperature under control. IT equipment consumes 50% of energy while the cooling system consumes approximately 37% of energy. Hence, it is very important to ensure the cooling of the data center is efficient. In this research, the effect of operating parameters such as inlet velocity, inlet temperature and porosity of the racks on the temperature distribution is studied; furthermore, the effect of different load distribution in the racks and the transient effects during load change are studied. A raised floor data center is modeled and thermal simulation is done using ANSYS FLUENT. The research consists of two parts, the first part aims at developing a working steady state model of a data center by modeling the racks as porous media and studying the temperature distribution of the racks and the room with varying load and different operating parameters for steady state condition. The optimal load distribution on the racks for different utilization is identified. In the second part, a transient state analysis is done in order to understand the change in the system when the load changes. In a data center, the racks do not always operate at 100% and hence most of the temperature issues come when the load increases suddenly. Therefore, it is important to study the transient effects when the load is increased.
Subject (authority = RUETD)
Topic
Mechanical and Aerospace Engineering
RelatedItem (type = host)
TitleInfo
Title
Rutgers University Electronic Theses and Dissertations
Identifier (type = RULIB)
ETD
Identifier
ETD_8815
PhysicalDescription
Form (authority = gmd)
electronic resource
InternetMediaType
application/pdf
InternetMediaType
text/xml
Extent
1 online resource (x, 54 p. : ill.)
Note (type = degree)
M.S.
Note (type = bibliography)
Includes bibliographical references
Subject (authority = ETD-LCSH)
Topic
Data processing service centers--Cooling
Note (type = statement of responsibility)
by Arvindh Sunder
RelatedItem (type = host)
TitleInfo
Title
School of Graduate Studies Electronic Theses and Dissertations
Identifier (type = local)
rucore10001600001
Location
PhysicalLocation (authority = marcorg); (displayLabel = Rutgers, The State University of New Jersey)
NjNbRU
Identifier (type = doi)
doi:10.7282/T3765JRQ
Genre (authority = ExL-Esploro)
ETD graduate
Back to the top

Technical

RULTechMD (ID = TECHNICAL1)
ContentModel
ETD
CreatingApplication
Version
1.7
ApplicationName
Microsoft® Word 2016
DateCreated (point = start); (encoding = w3cdtf); (qualifier = exact)
2018-04-10T17:24:04
DateCreated (point = end); (encoding = w3cdtf); (qualifier = exact)
2018-04-10T17:24:04
Back to the top
Version 8.5.5
Rutgers University Libraries - Copyright ©2024